Home Shop Collections Contact Us Post a Deal

Our product rankings are based on analysis of thousands of customer reviews, brand reputation, pricing trends, and popularity data. They represent our honest opinion and are intended as a helpful starting point for your research. Some links on this site are affiliate links — if you buy through them, we may earn a small commission at no extra cost to you. This helps us keep the site free and up to date.

Dylos DC1100 Pro Air Quality Monitor (450g, Black)

Laser Particle Counter

From: Dylos

The Dylos DC1100 Pro delivers professional-grade air quality monitoring for your home. This true laser particle counter measures both small particles like bacteria and mould alongside larger particles such as pollen.

The LCD screen displays real-time particle counts with a dynamic bar graph showing actual readings. Multiple monitoring modes include minute, hour, day and continuous monitoring to track air quality patterns.

What sets this model apart is its enhanced sensitivity detecting particles down to 0.5 microns. The device stores up to 30 days of air quality history and calibrates large particles at 2.5 microns and above for precise measurements.


Check Price
Amazon UK

Product Features

True Laser Particle Counter - Uses genuine laser technology rather than basic optical sensors found in cheaper alternatives. This provides laboratory-grade accuracy comparable to professional equipment costing thousands more. The laser system counts individual particles passing through the detection chamber, giving you scientifically reliable data for making informed decisions about your indoor air quality. Dual Size Detection - Monitors both small particles (0.5+ microns) including bacteria and mould spores, plus large particles (2.5+ microns) like pollen and dust. This dual-range capability helps identify specific pollution sources. Small particle counts indicate biological contaminants whilst large particle readings show dust and allergen levels, enabling targeted air purification strategies. Enhanced 0.5 Micron Sensitivity - The Pro model detects particles down to 0.5 microns compared to standard models with higher thresholds. This increased sensitivity captures fine particulates that standard air quality monitors miss. These tiny particles penetrate deep into lungs and are particularly harmful for asthma sufferers and people with respiratory conditions.
30-Day Data Storage - Automatically stores air quality readings for up to 30 days, allowing you to track patterns and trends over time. This historical data helps identify pollution sources, evaluate air purifier effectiveness and understand how activities like cooking or cleaning affect indoor air. The stored data proves invaluable for managing respiratory conditions effectively. Multiple Monitoring Modes - Offers minute, hour, day and continuous monitoring modes to suit different measurement needs. Minute mode provides instant feedback for testing air purifiers or identifying immediate pollution sources. Day mode tracks longer-term trends whilst continuous monitoring maintains ongoing air quality surveillance for health-conscious households. LCD Display with Bar Graph - Features a clear LCD screen showing particle counts alongside a dynamic bar graph for visual representation. The real-time display eliminates guesswork about air quality levels. The bar graph provides instant visual feedback, making it easy to see when particle counts spike and when air purification efforts are working effectively.

FAQs

How accurate is the DC1100 Pro compared to professional equipment?

The DC1100 Pro provides remarkably accurate readings that match professional particle scanners costing £3000+. Independent testing by users with access to laboratory-grade equipment shows virtually identical particle count readings. The true laser technology and calibrated detection chambers ensure scientific accuracy suitable for serious air quality monitoring and respiratory health management.

What's the difference between small and large particle readings?

Small particles (0.5+ microns) include bacteria, mould spores, smoke and fine dust that penetrate deep into lungs. Large particles (2.5+ microns) encompass pollen, pet dander and coarse dust that typically affect upper respiratory systems. Monitoring both ranges helps identify specific pollution sources and choose appropriate filtration strategies for different contaminants.

Can humidity affect the particle count readings?

Yes, high humidity can influence readings as the device cannot distinguish between water droplets and dust particles. This is common with all optical particle counters. For most accurate results, use the monitor for before/after comparisons in similar humidity conditions rather than absolute measurements during significant humidity changes. The readings remain valuable for tracking air quality trends and purifier effectiveness.

How do I interpret the particle count numbers?

Typical indoor baseline readings range from 30,000-160,000 particles per cubic foot. Clean air from quality HEPA filters should show near-zero readings. Outdoor air often measures 200,000+ particles. Readings above 80,000 indoors suggest poor air quality requiring filtration. The 30-day storage helps establish your home's baseline for meaningful comparisons.

Will this help me manage my air purifier more effectively?

Absolutely. The monitor eliminates guesswork about air purifier performance and optimal fan speeds. You can test different settings to find the minimum speed maintaining good air quality, reducing energy costs and noise. The device also indicates when filters need replacement based on actual performance rather than manufacturer timelines, potentially extending filter life significantly.

Does the DC1100 Pro work with 240V UK power supply?

The device requires 120V power supply and comes with a US-style plug. UK users need a suitable voltage converter and plug adapter for safe operation. The power requirements are clearly stated as "Only for use with 120V" so ensure you have proper voltage conversion before use to avoid damage.

How long does the device store air quality data?

The internal memory stores up to 30 days of air quality history across all monitoring modes. This historical data helps identify patterns, track improvement after installing air purifiers and understand how daily activities affect indoor air quality. The stored information proves invaluable for people managing asthma or allergies through air quality control.

What activities typically cause particle count spikes?

Cooking at high temperatures, vacuuming, dusting and opening windows near busy roads commonly increase particle counts. Outdoor activities like gardening can introduce particles when you re-enter the home. The monitor helps identify which household activities require increased air filtration and how long elevated particle levels persist after various activities.

Dylos DC1100 Pro Air Quality Monitor (450g, Black) Specs

BrandDylos
ModelDC1100 Pro
Particle Detection Range0.5 microns and above
Large Particle Calibration2.5 microns and above
Detection TechnologyTrue laser particle counter
Display TypeLCD screen
Display FeaturesDynamic bar graph
Monitoring ModesMinute, hour, day, monitor
Data Storage30 days air quality history
Power Requirements120V only
Included ComponentsPower cord and adapter
Batteries RequiredNo
Batteries IncludedNo
Item Weight450g
Product Dimensions11.43 x 7.62 x 17.78 cm
Package Quantity1
ManufacturerSNUNGPHIR
Part Numberuk0207-642
ASINB004AWEG0Y
Date First Available4 September 2012
Particle Size RangesSmall and large particles
Air Flow MethodPC-style fan
Measurement UnitParticles per cubic foot
Real-time DisplayYes
Historical Data ReviewYes